CRC14/CRR14


14 SEER/2-5 TONS
SPLIT SYSTEM CONDENSING UNIT
24,000-60,00 Btu/h Cooling Capacity

Uninterrupted Power Supply (UPS) option for regions with unsteady main power supply

DESIGN FEATURES:

  • Oval coil design suppresses flow recirculation, separation and corner singularities for high energy efficiency+
  • R-410A Environment friendly refrigerant
  • Energy-efficient single and two-stage scroll compressors
  • Design classifications are based on Capacity and Efficiency
  • High performance PSC and ECM motors
  • Rifled copper tube/enhanced aluminum lanced fin
  • High and low pressure switches for equipment protection
  • Equipped with Emerson Comfort Alert Diagnosis
  • Powdered coated cabinet to prevent rust
  • Easy access to covered and protected service valves
  • Sound level in 70-75 dBA range with compressor blanket
  • Conform to AHRI/ASHRAE Standards
  • Meet Energy-Star ratings


CONDENSING UNIT NOMENCLATURE:

CR Product Type
C Cabinet Configuration
14 Unit Efficiency
030 Unit Capacity
C Operating Mode
A Series Revision
1 Compressor Type
1 Condenser Motor Type
1 Throttling Device
1 Voltage

Product Type
CR = Condensing Unit for Residential Split System

Cabinet Configuration
C = Circular/Oval
R= Rectangular

Unit Efficiency
(Seasonal Energy Efficiency Rating – SEER)
13 – 13 SEER
14 – Up to 14 SEER
15 – Up to 15 SEER
16 – Up to 16 SEER
17 – Up to 17 SEER
18 – Up to 18 SEER
21 – Up to 21 SEER

Unit Capacity (Nominal)
024 = 2 Tons (24,000 Btu/h)
030 = 2 ½ Tons (30,000 Btu/h)
036 = 3 Tons (36,000 Btu/h)
042 = 3 ½ Tons (42,000 Btu/h)
048 = 4 Tons (48,000 Btu/h)
060 = 5 Tons (60,000 Btu/h)

Operating Mode
C= Cool Only
H= Heat Pump

Series Revision
Coil Configuration, etc.
(Contact Manufacturer)

Compressor Type
1 – R410A Single Stage (1 Speed) Copeland Scroll Compressor
2 – R410A Two Stage (2 Speeds) Copeland Scroll Compressor
3 – R410A Digital (Variable Speeds) Copeland Scroll Compressor

Condenser Motor Type
1 – PSC, GE
2 – ECM, GE

Throttling Device
1 = Thermostatic Expansion Valve (TXV)
2 = Automatic Expansion Valve (AXV)
3 = Orifice (Piston) Expansion Valve

Voltage Type
1 – 208/230 V, 1 Ph., 60 Hz.
2 – 208/230 V, 1 Ph., 50 Hz.
3 – 208/230 V, 3 Ph., 60 Hz.
4 – 480 V, 3 Ph., 60 Hz.
5 – 460/230 V, 3 Ph., 60 Hz.
6 – 380/415 V, 3 Ph., 50 Hz.
7 – 575V, 3 Ph., 60Hz.


CONDENSING UNIT SPECIFICATIONS:

MODEL CRC14024
CRR14024
CRC14030
CRR14030
CRC14036
CRR14036
CRC14042
CRR14042
CRC14048
CRR14048
CRC14060
CRR14060
Unit Capacity
Nominal Cooling Capacity, Btu/h 24,000 30,000 36,000 42,000 48,000 60,000
SEER Nominal <————————————————-Up To 14————————————————>
Compressor <———————————————Copeland Scroll———————————————>
RLA 13.5 12.8 14.1 17.9 19.9 26.4
LRA 58.3 64.0 77.0 112.0 109.0 134.0
Refrigeration System
Refrigerant Type <————————————————-R-410A————————————————->
Refrigerant Line Set
Liquid Line Diameter 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”
Suction Line Diameter 3/4” 3/4” 3/4” 7/8” 7/8” 7/8”
Discharge Line Diameter 1/2″ 1/2″ 1/2″ 1/2″ 1/2″ 1/2″
Throttling Device <—————————————————-TXV—————————————————>
TXV Size 2 Ton 2 Ton 3 Ton 3 Ton 4 Ton 5 Ton
Liquid Valve Connection 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”
Suction Valve Connection 3/4” 3/4” 3/4” 7/8” 7/8” 7/8”
Refrigerant Charge++ (lbs.) 6.50 6.52 7.56 7.66 8.68 8.76
Condenser Fan Motor
Rated HP 1/10 1/10 1/4 1/5 1/4 1/4
Rated RPM 1100 1100 1075 1075 1075 1075
Air-flow Rate (ACFM) 2207 2201 3105 3125 3835 3830
Rated FLA 0.75 0.75 1.10 1.10 1.60 1.60
Condenser Coil^
Model Number CR361002413 CR361002413 CR361052414 CR361052414 CR401102216 CR401102218
Face Area, Sq. Ft 25 25 26.25 26.25 30.56 30.56
Electrical Data
Voltage/Phase-Hz 208/230/1-60 208/230/1-60 208/230/1-60 208/230/1-60 208/230/1-60 208/230/1-60
MCA/MOP** 17.6/30 16.8/30 18.7/30 23.5/40 26.5/45 34.6/60
Sound Power (dBA) 73 73 74 77 77 79
Models CRC14024 CRC14030 CRC14036 CRC14042 CRC14048 CRC14060
Installed/Shipping Weight 207/222 208/223 223/238 244/264 285/305 289/309
Models CRR14024 CRR14030 CRR14036 CRR14042 CRR14048 CRR14060
Installed/Shipping Weight 218/233 219/234 239/254 260/280 304/324 308/328

+in lbs. (subject to change) ^ Condenser Coil Configuration (Contact Manufacturer) ++Unit Full Charge includes 25Ft of Liquid and Suction Line Set. **Minimum Circuit Ampacity/Maximum Overcurrent Protection

CONDENSING UNIT DIMENSIONS AND HVAC ENGLISH TO METRIC UNITS CONVERSION TABLE:

C-Series-Graph-Final

 

 

CRC DIMENSIONS+
MODEL L W H
CRC14024 42.01 37.25 36.25
CRC14030 42.01 37.25 36.25
CRC14036 43.69 38.88 36.25
CRC14042 43.69 38.88 36.25
CRC14048 46.60 40.50 40.25
CRC14060 46.60 40.50 40.25
CRR DIMENSIONS+
MODEL L W H
CRR14024 37.25 36.50 36.25
CRR14030 37.25 36.50 36.25
CRR14036 39.25 38.50 36.25
CRR14042 39.25 38.50 36.25
CRR14048 41.25 40.50 40.25
CRR14060 41.25 40.50 40.25

*DIMENSIONS in inches

CRC14-&-CRR14